ACRYLAMIDE
Organic Service Branch II 1. General Discussion
The necessity for additional information on the sampling and analysis of acrylamide became apparent because of several factors. Since the development of the acrylamide method, different kinds of samplers have become available. The sensitivity of the method needed to be checked, because the PEL has been changed from 0.3 mg/m3 to 0.03 mg/m3. Also, there were some questions about the stability of acrylamide on a sampler when exposed to elevated temperatures. The sensitivity of the existing method was investigated because of the lower PEL. (Ref. 5.1.) After reviewing the method it appeared to have a detection limit around one seventh of the PEL based on the recommended air volume and desorption volume. Further investigation was done on a gas chromatograph and the detection limit was found to be 0.7 µg/mL, which calculates to be 0.006 mg/m3 for a 1-mL desorption volume or 0.029 mg/m3 for a 5-mL desorption volume based on a 120 L air volume. This level was insufficient for use with OVS type samplers and for air volumes less than 120 L. Therefore a published liquid chromatography procedure was tried which yielded better sensitivity. (Ref. 5.3.)
The stability of acrylamide was tested on the OVS samplers with different types of resins. Several front sections
of various types of the OVS sampler configuration were tested for the stability of acrylamide. The types tested
were After storage the samples were desorbed with 2 mL of methanol and analyzed by the gas chromatography method. The results are listed in the following tables.
OVS-2 Room Temperature
OVS-2 Oven Temperature (45°C)
OVS-7 Room Temperature
OVS-7 Oven Temperature (45°C)
OVS-SG Room Temperature
OVS-SG Oven Temperature (45°C)
The above data shows that acrylamide is stable on the different resins for four days at 45°C. The stability could change at higher temperatures or by exposing the samples to UV light. 1.1.2. Toxic effects (This section is for information only and should not be taken as the basis of OSHA policy.) Acrylamide exposure comes from inhalation and absorption through the skin. Repeated exposure to acrylamide will effect the central nervous system. Some of the symptoms from exposure are muscular weakness, ataxia, in coordination, tremors, and hallucinations. Also, there is some evidence that acrylamide is carcinogenic in rats and it is assigned to a suspect human carcinogen list. (Ref. 5.4.) 1.1.3. Potential workplace exposure Acrylamide is a reactive monomer that is used in the production of organic chemicals. Also, it is used as a polymer or copolymer in applications as adhesives, fibers, paper sizing, molded parts, water coagulant aids, and textiles. (Ref. 5.4.) There is a potential for approximately 20,000 workers to be exposed to acrylamide. (Ref. 5.1.) 1.1.4. Physical properties (Ref. 5.1. to 5.3.)
1.2. Limit defining parameters The detection limit of the analytical procedure is 0.75 ng per injection. This is the amount of analyte which will give a peak whose height is approximately five times the baseline noise. (Figure 2.) 2. Sampling Procedure
2.1.2. OVS-7 tubes, which are specially made 13-mm o.d. glass tubes that are tapered to 6-mm o.d., packed with two sections of cleaned XAD-7 adsorbent and a 13-mm diameter glass fiber filter. The sampling section and backup section contain 270 and 140 mg respectively. The backup section is retained by two foam plugs and the sampling section is between a foam plug and the glass fiber filter. The glass fiber filter is held next to the sampling section by a polytetrafluoroethylene (PTFE) retainer. (Figure 2.) 2.2. Reagents No sampling reagents are required. 2.3. Sampling technique
2.3.2. Attach the small end of the tube to the sampling pump with flexible tubing. 2.3.3. Attach the tube vertically in the employee's breathing zone in such a manner that it does not impede work performance. 2.3.4. After sampling for the appropriate time, remove the tube and seal it with plastic caps. 2.3.5. Wrap each sample end-to-end with an OSHA seal (Form 21). 2.3.6. Record the air volume for each sample, and list any possible interferences. 2.3.7. Submit at least one blank for each set of samples. Handle the blank in the same manner as the samples, except no air is drawn through it. 2.3.8. Submit bulk samples for analysis in a separate container. Do not ship with air samples. 2.4. Extraction efficiency Six vials containing an amount of XAD-7 resin equivalent to the front section of an OVS-7 tube and a 13-mm glass fiber filter were each liquid-spiked with 4.003 µg of acrylamide. These samples were allowed to dry in a drawer overnight. The next day these vials were each desorbed with 5.0 mL of a solution containing 5% methanol 95% water, shaken for 30 min and then analyzed as in Section 3. The results are listed in Table 2.4.
Extraction Efficiency
2.5. Retention efficiency Eighteen OVS-7 tubes were liquid-spiked with 4.003 µg of acrylamide. These were allowed to equilibrate overnight in a drawer. The next day these tubes were placed on a humid air generator and 120 L of humid air (~76% relative humidity) were drawn through each tube at 1 L/min. Six of the tubes were each desorbed with 5.0 mL of a solution containing 5% methanol 95% water, shaken for 30 min and then analyzed as in Section 3. The remaining samples were stored 6 in a drawer at ambient temperature and 6 in a freezer for use in a storage study below. The results are listed in Table 2.5.
Retention Efficiency
2.6. Sample storage After 7 days of storage, 6 samples were each desorbed with 5.0 mL of a solution containing 5% methanol 95% water, shaken for 30 min and then analyzed as in Section 3. Three of the samples were from ambient storage and the other three were from the freezer storage samples. The remaining samples were analyzed after 13 days of storage. The results are given in Tables 2.6.1. and 2.6.2.
Ambient Storage
Freezer Storage
2.7. Recommended air volume and sampling rate
2.7.2. The recommended flow rate is 1.0 L/min. 2.8. Interferences (sampling) It is not known if any compounds will interfere with the collection of acrylamide. Any suspected interferences should be reported to the laboratory. 2.9. Safety precautions (sampling)
2.9.2. Follow all safety practices that apply to the work area being sampled. 3. Analytical Procedure
3.1.2. A mechanical shaker. 3.1.3. An HPLC equipped with a UV detector. A Hewlett Packard (HP) 1090M equipped with an autosampler and diode array detector was used in this evaluation. 3.1.4. An HPLC column capable of separating acrylamide from any interferences. A 25 cm × 4.6 mm i.d. Zorbax ODS (5 µm) liquid chromatography column was used in this evaluation. 3.1.5. An electronic integrator, or some other suitable means for measuring detector response. The Hewlett-Packard 1090M Data System was used in this evaluation. 3.1.6. Volumetric flasks and pipets. 3.1.7. Vials, 2-mL and 7-mL. 3.2. Reagents
3.2.2. Acrylamide, reagent grade, obtained from J. T. Baker was used in this evaluation. 3.2.3. Water, HPLC grade, Milli-Q filtered water, Millipore Inc. 3.3. Standard preparation Prepare stock standards by weighing 10 to 15 mg of acrylamide. Transfer the acrylamide to separate 10-mL volumetric flasks, and add a solution containing 5% methanol 95% water to the mark. Make working range standards of 2.0 to 185 µg/mL by diluting the stock standards with a solution containing 5% methanol 95% water. Store stock and diluted standards in a refrigerator. 3.4. Sample preparation
3.4.2. Add 5.0 mL of a solution containing 5% methanol 95% water to each vial and seal with a Teflon-lined cap. 3.4.3. Shake the vials for 30 minutes on a mechanical shaker. 3.4.4. If necessary, transfer the samples to 2-mL vials for use on an HP autosampler. 3.5. Analysis
3.5.2. Chromatogram (Figure 3.) 3.6. Interferences (analytical)
3.6.2. HPLC conditions may generally be varied to circumvent interferences. 3.6.3. Retention time on a single column is not proof of chemical identity. Analysis on an alternate HPLC column and confirmation by mass spectrometry are additional means of identification. 3.7. Calculations
3.7.2. Determine the µg/mL of acrylamide in each sample and blank from the calibration curve. 3.7.3. Blank correct each sample by subtracting the µg/mL found in the blank from the µg/mL found in the sample. 3.7.4. Determine the air concentration by using the following formula.
3.8. Safety precautions (analytical)
3.8.2. Avoid skin contact with all solvents. 3.8.3. Wear safety glasses at all times. 4. Recommendation for Further Study This method should be fully validated.
![]()
UV Scan of Acrylamide in Mobile Phase ![]()
Detection Limit Chromatogram of Acrylamide at 200 nm ![]()
Chromatogram of Acrylamide at 200 nm ![]()
Calibration Curve 5. References
5.2. Merck Index, 10th ed.; Windholz, Martha Ed.; Merck: Rahway, NJ, 1983; p 19. 5.3. Skelly, Norman E. and Husser, Edward R.; Anal. Chem; 1978, 50, 1959-1962. 5.4. Documentation of the Threshold Limit Values and Biological Exposure Indices; American Conference of Governmental Industrial Hygienists Inc., Fifth Edition, 1986, pp. 12-13. |