PHENOTHIAZINE
SOLVENTS BRANCH 1. General Discussion
The PEL for phenothiazine is 5 mg/m3. Since phenothiazine is a solid at room temperature, collection on a glass fiber filter was tried and found successful. There was no loss of phenothiazine in the retention studies. The extraction, and storage studies were near 100%. 1.1.2. Potential workplace exposure (Ref. 5.1.) Phenothiazine is used as a pesticide, and is used orally to treat pinworm, threadworm, and roundworm infestations. It is used as a base for the manufacture of pharmaceuticals. It is used as a urinary antiseptic. 1.1.3. Toxic Effects (This section is for information purposes and should not be taken as the basis for OSHA policy.)(Ref. 5.1.)
Oral doses of 1 or more grams per day may cause toxic hepatitis, hemolytic anemia, abdominal
cramps, tachycardia, gastrointestinal and skin irritation, skin photosensitization, kidney
damage, and pruritus. Workers applying phenothiazine in orchards reported skin
irritation, including itching, and redness on any exposed surface. The photosensitizing dose is
less than 0.75 grams. Workers exposed to between 15 and 48 mg/m3 during pulverizing and packaging
phenothiazine dust developed 1.1.4. Physical properties (Ref. 5.2.):
1.2. Limit defining parameters
1.2.2. The overall detection limit is 0.03 mg/m3, based on a 3 mL extraction and a 100 liter air volume. (All mg/m3 amounts in this study are based on a 100 liter air volume and a 3 mL desorption.) 1.3. Advantages
1.3.2. The analytical method is reproducible and sensitive. 1.3.3. Reanalysis of samples is possible. 1.3.4. It may be possible to analyze other compounds at the same time. 1.3.5. Interferences may be avoided by proper selection of column and GC parameters. 1.4. Disadvantages none known 2. Sampling procedure
2.1.2. A 2.2. Sampling technique
2.2.2. Connect the filter cassette to the sampling pump with flexible tubing. 2.2.3. Air being sampled should not pass through any hose or tubing before entering the cassette.
2.2.4. Seal the ends of the cassette with plastic caps immediately after sampling. Seal each sample
lengthwise with OSHA 2.2.5. With each batch of samples, submit at least one blank filter from the same lot used for samples. This filter should be subjected to exactly the same handling as the samples except that no air is drawn through it. 2.2.6. Transport the samples (and corresponding paperwork) to the lab for analysis. 2.2.7. Bulks submitted for analysis must be shipped in a separate mailing container from the samples. 2.3. Extraction efficiency
Six glass fiber filters were liquid spiked at each
loading of 16.56 µg (0.4968 mg/m3), 82.8 µg (2.484
mg/m3), and 165.6 µg (4.968 mg/m3) phenothiazine. They
were allowed to equilibrate overnight at room
temperature. They were opened, placed into a 4 mL vial,
extracted with 3 mL of methyl
Desorption Efficiency
2.4. Retention efficiency
Six glass fiber filters were liquid spiked with 165.6 µg
(4.968 mg/m3) phenothiazine. They were placed in a
cassette with a second glass fiber filter, and a spacer
between the two filters. They were allowed to
equilibrate overnight , and had 100 liters humid air (90%
RH) pulled through them. They were opened, extracted, and
analyzed by
Retention Efficiency
2.5. Storage Glass fiber filters were spiked with 165.6 µg (4.968 mg/m3) phenothiazine and stored at room temperature on the benchtop until opened and analyzed. Half of the storage samples were stored in brown vials, as phenothiazine decomposes in sunlight. The storage samples were exposed to room light. There was little difference between the samples stored in brown and clear glass. The spectrum of room light does not compare to sunlight, so this comparison probably does not mimic sunlight conditions. The recoveries averaged 98.9% for brown glass vials, and 99.6 % for clear glass vials for the 14 days stored (Table 3).
Storage Study
2.6. Precision The precision was calculated using the area counts from six injections of each standard at concentrations of 16.56, 82.8, 165.6, and 331.2 µg/mL. The pooled coefficient of variation was 0.0152 (Table 4).
Precision Study
where:
A(1), A(2),A(3),A(4) = # of injections at each level 2.7. Air volume and sampling rate studied
2.7.2. The sampling rate studied is 1.0 liter per minute. 2.8. Interferences Suspected interferences should be listed on sample data sheets. 2.9. Safety precautions
2.9.2. Safety glasses should be worn at all times. 2.9.3. Follow all safety practices that apply to the workplace being sampled. 3. Analytical method
3.1.2. GC column capable of separating the analyte from any interferences. The column used in this study
was a 60 M 3.1.3. An electronic integrator or some other suitable method of measuring peak areas.
3.1.4. Two and four milliliter vials with 3.1.5. A 10 µL syringe or other convenient size for sample injection.
3.1.6. 3 mL pipets for dispensing the methyl 3.1.7. Volumetric flasks - 10 mL and other convenient sizes for preparing standards. 3.1.8. Analytical balance capable of weighing milligram amounts. 3.2 Reagents
3.2.2. Methyl 3.2.3. Phenothiazine, Reagent grade 3.3. Sample preparation
3.3.2. The filter is extracted with 3 mL of methyl 3.3.3. The vials are sealed immediately and allowed to extract 30 minutes with occasional shaking. 3.3.4. An aliquot is placed in a 2 mL vial for analysis. 3.4. Standard preparation
3.4.2. A series of standards are prepared covering the range from detection limit to the highest sample. At least five different concentrations should be made so that there are enough data points to plot a curve. The range used in this study was 1.656 to 165.6 µg/mL. 3.5. Analysis
3.5.2. Peak areas are measured by an integrator or other suitable means. 3.6. Interferences (analytical)
3.6.2. Retention time data on a single column is not considered proof of chemical identity. Samples over the target concentration should be confirmed by GC/Mass Spec or other suitable means. 3.7. Calculations
3.7.2. The area counts for the samples are plotted with the calibration curve to obtain the concentration of phenothiazine in solution. 3.7.3. To calculate the air concentration of phenothiazine (PT) the following equation is used:
where :
3.8. Safety precautions
3.8.2. Avoid skin contact with all solvents. 3.8.3. Wear safety glasses at all times. 4. Recommendations for further study
Collection studies should be performed. Analysis of phenothiazine can also be done by liquid chromatography
according to literature.
5. References
5.2. Windholz, M., "The Merck Index", Tenth Edition, Merck & Co., Rahway N.J., 1983, p. 1046. |